| Water distribution systems |
| Piping |
PE water pipes in the floor and walls, backbone distribution systems and horizontal piping, stop valves, insulation |
| Fixtures and fittings |
| Washbasins |
Subway, white, 55 x 43cm |
| Air trap |
Viega, bottle, 11/4” x 120 mm, chrome |
| Angle valves for hot and cold water distribution |
ARCO valve, stop angle, 1” x 3/8” threaded |
| Small basin |
Subway, white, 37 x 29cm |
| Bathtub |
Enameled, 1800 x 800 mm, white |
| Air trap |
Side inlet, complete air trap with a drain, stainless / chrome |
| Bathtub pads |
Part of the bathtub delivery |
| Shower enclosure |
Brickwork, ceramic tiling and paving |
| Shower screen |
Glass, hardware, anchoring, molding - chrome |
| Air trap and accessories to the shower enclosure |
Floor, round air trap with peripheral water outlet, stainless / Chrome-plated |
| Hot and cold water distribution to the bathtub and the shower |
Part of the concealed fitting |
| WC bowl |
Subway, white, suspended, horizontal drain |
| WC - seat |
Plastic, white color |
| Built-in WC module system – flush reservoir |
Kombifix |
| Flush control |
Chrome-plated, Tango |
| Bidet |
Subway, white, suspended, single-hole |
| Bidet console |
AZP KB 1 accessories sensor |
| Mixers |
| Basin mixer |
Talis S, stand, lever, chrome |
| Small basin mixer |
Talis S, stand, lever, chrome |
| Bidet Mixer |
Talis S, stand, lever, chrome |
| Shower mixer |
Talis S, hidden, lever, chrome |
| Shower – hose + shower head + support |
The Mistral Unica D set (a separate shower support with the Isiflex B 27930 hose, the Porter D 27R526 shower holder and the Mistral 28590 shower head) |
| Bathtub mixer |
Talis S, hidden, lever, chrome |
| Hot service water preparation |
Indirectly heated tank, preferably in the boiler standard as a proprietary solution, forced circulation |
| Sewage |
| Sewer connection |
Material and design according to the PD project |
| Horizontal piping |
Material and design according to the PD project |
| Connection pipes to fixtures and fittings |
Material and design according to the PD project |
| Vertical piping (drains) |
Material and design according to the PD project |
| Rainwater sewer pumping - retention |
Outdoor concrete prefa tank with a safety overflow (volume 2 to 6 m3, depending on the building); a sludge pump + accessories |
| Wastewater drainage |
Proprietary pumping boxes + all the accessories |
| Roof inlets |
Proprietary, heated |
| Heating |
| Piping |
Central heating pipes – copper, installed in the floor and the walls, insulated; gas – steel seamless pipes in grooves in the masonry |
| Boiler |
Gas boiler, on lower floors atmospheric, under the roof a turbo system (depending on the location) |
| Heaters |
Flat panel heaters with bottom connection, white color |
| Above-the-floor convectors |
Bottom connection, white color |
| Thermostatic heads |
Standard, white color |
| Floor heating – big bathrooms with a bathtub |
Electric heating with a thermostat-based programmed control |
| Tubular heater |
hot-water heater with an electronic cartridge for summer operation, white color |
| Chimney |
Three-component masonry ceramic or assembled “sheet metal” |
| Measurement and regulation |
A M&R system as recommended by the manufacturer of the boiler |
| Gas |
| Piping |
Material and design according to the PD project |
| Electrical installations - Heavy current |
| Cables |
Power cables concealed under the plaster - copper |
| Distribution board |
Built-in, with excess voltage protection, 3 x 25A |
| Lightning conductor |
Hidden in a pipe under the plaster, fixed to the attic sheet metal on the roof |
| Sockets – habitable rooms |
Height 300 mm above the floor |
| Sockets - service rooms |
Height 300 mm above the floor (1 x three-phase socket in the garages) |
| Switches – habitable rooms |
Height 1050 mm above the floor |
| Switches - service rooms |
Height 1050 mm above the floor, white color |
| Interior lights – habitable rooms with natural lighting |
An outlet only |
| Interior lights – habitable rooms without natural lighting |
A holder with a bulb only |
| Interior lights – technical rooms |
|
| Electrical installations - Weak current |
| Home intercom |
Home intercom on each floor and at the entrance gate, arrangements for a videophone – the entrance gate in the fence + the main habitable floor |
| Data and phone network |
Cabling designed as universal, preparation according to the PD in each habitable room |
| Common TV aerials |
Cabling is designed as universal, a TV set can be connected to the common TV aerial in each inhabitable room, there are arrangements for the installation of an aerial or a satellite dish on the roof (the aerial, the satellite dish is not included in the delivery) |
| Weak current sockets |
Height 300 mm above the floor, sockets situated according to the PD |
| Ventilation and Air conditioning (VAC) |
| Ventilation fans + VAC grille |
Ventilation fans with a concealed jacket under the plaster, single speed, with a back flap, controlled by a separate switch |
| Kitchens |
| Wiring |
Connection points according to the PD, kitchen fitments are not included in the delivery |
| Exterior |
| Fencing along the roads |
Concrete foundations, fencing consisting of stone baskets – gabions, combined with galvanized steel fencing |
| Fencing between the plots |
Galvanized steel pillars and galvanized steel wire screen |
| Separating walls between the buildings on the 1st UF, ground floor and the 2nd floor |
A concrete wall or a galvanized steel grate structure with wooden filling, impregnated to protect against weather conditions |
| Outdoor entrance gates to the plot |
Two-leaf or four-leaf gates including the hinges and landing, a galvanized steel structure, including the driving units, remote controllers |
| Pathways and hard surfaces on the plots |
Granite paving |
| Outdoor staircase on the garden plots |
Reinforced concrete structure including a steel rail, anti-skid design |
| Weather pathways along the facade of the buildings |
Concrete edge stone border filled with washed river stones |